The here listed additional information should help you with a problem solution. However, an assurance for the correctness or wholeness of the statements doesn´t exist.

facility:
The feature of a Calls as well as within a Registration consists from the Facility-Length (1 byte) and the Facility-Field (0 ..63 bytes). By means of these statements, specific parameters can be arranged in term.
Here a short overview: (Numbers in HEX)

Length

Code

Para 1

Para 2

Para x

Facility

00

without Facility

02

01

01

Reverse charging

02

01

x0

Fast select

02

01

x1

Reverse charging and Fast select

02

02

xy

Throughput class

02

03

xx

Closed User Group selection

02

04

01

Charging information request

02

08

0x

Called line address modification

02

09

xx

Closed User Group outgoing selection

03

41

xx

xx

Bilateral Closed User Group selection

03

42

sp

rp

Paket size negotiation

03

43

sw

rw

Window size negotiation

03

44

xx

xx

RPOA selection

03

47

xx

xx

Closed User Group selection (ext.)

03

48

xx

xx

Closed User Group outgoing selection (ext.)

03

49

xx

xx

Transitdelay selection and indication

03

4C

st

rt

Throughput class (ext.)

xx

C1

..

..

..

Charging indication call duration

xx

C2

..

..

..

Charging indication segment count

xx

C3

0x

..

..

Call redirection/deflection notification

xx

C4

..

..

..

RPOA selection (ext.)

xx

C5

..

..

..

Charging indication monetary unit

xx

C6

..

..

..

NUI selection

xx

D1

Cx

..

..

Call deflection to X25 number

xx

FF

reserved



Protocol Identifier:
Broadly ale has User-data-field a length of 0 ..16 bytes the option and serves the transmission of beforehand information at the goal system.
If the bits are 7 and 6 of the first byte ZERO, the only 4 bytes serve as Protocol-Identifier for higher protocol layers, for example 01-00-00-00 for the PAD - followed from 12 bytes of User-Data as Logon-ID or Routing-Information for the PAD. (Numbers in HEX)

Byte 0

Byte 1

Byte 2

Byte 3

Protocol

01

00

00

00

Async. CCITT

10

00

00

00

X3

C2

00

00

00

SNA LLC2 (PSH)

C3

00

00

00

SNA QLLC

CC

00

00

00

TCP/IP


 

Clearing Causes:

Code in HEX

Reason

00

DTE originated

01

Number Busy

03

Invalid Facilty Request

05

Network Congestion

09

Out of Order

0B

Access Barred

0D

Not Obtainable

11

Remote Procedure Error

13

Local Procedure Error

15

RPOA Out of Order

19

Collect Call Refuse

21

Incomptible Destination

29

Fast Select not Subscribed

39

Ship absend

41

Buffer Overrun


 

Reset Causes:

Code in HEX

Reason

00

DTE originated

01

Out of Order (PVC)

03

Remote Procedure Error

05

Local Procedure Error

07

Network Congestion

09

Remote DTE Operational (PVC)

0F

Network Operational (PVC)

11

Incompatible Destination

1D

Network Out of Order (PVC)


 

Restart Causes:

Code in HEX

Reason

00

DTE originated

01

Local Procedure Error

03

Network Congestion

07

Network Operational

7F

Registration/Cancellation Confirmed


 

Diagnostic Codes:

Code in HEX

Reason

00

No additional Infos

01

Invalid P(S)

02

Invalid P(R)

10

Paket-Type Invalid for (this State)

11

- for paket level ready (r1)

12

- for DTE restart request (r2)

13

- for DCE restart indication (r3)

14

- for DCE ready (p1)

15

- for DTE waiting (p2)

16

- for DCE waiting (p3)

17

- for data transfer (p4)

18

- for call collision (p5)

19

- for DTE clear request (p6)

1A

- for DCE clear indication (p7)

1B

- for flow-control ready (d1)

1C

- for DTE reset request (d2)

1D

- for DCE reset indication (d3)

20

Paket not allowed

21

Unidentifiable paket

22

CALL on One-way logical channel

23

Invalid Paket type on PVC

24

Paket on unassigned logical channel

25

REJECT not allowed

26

Paket too short

27

Paket too long

28

Invalid GFI

29

RESTART on channel unequal 00

2A

Paket type not compatible with facility

2B

Unauthorized Interrupt Confirmation

2C

Unauthorized Interrupt

2D

Unauthorized Reject

30

Timer expired

31

- on incomming call

32

- on clear indication

33

- on reset indication

34

- on restart indication

35

- on call deflection

40

CALL setup, clear or registration problem

41

Facility Code not allowed

42

Facility Parameter not allowed

43

Invalid called DTE address

44

Invalid calling DTE address

45

Invalid facility/registation length

46

Incomming Call barred

47

No logical channel avaible

48

Call collision

49

Dublicate Facility request

4A

Address length is not zero

4B

Facility length is not zero

4C

Expected Facility is not provided

4D

Invalid CCITT spezified DTE facility

4E

Maximum of call redirections exceeded

50

Miscellaneous / QLLC error (SNA)

51

Improper Cause code from DTE / Undefined C field (SNA)

52

Not aligned Byte / Unexpected C field (SNA)

53

Inconsistent Q-bit setting / Missing I field (SNA)

54

NUI problem / Undefined I field (SNA)

55

I-field too long (SNA)

56

QFRMR received (SNA)

57

Invalid QLLC header (SNA)

58

Data received in none-data state (SNA)

59

Timeout condition (SNA)

5A

Invalid number (number received) (SNA)

5B

Recovery rejected or terminated (SNA)

5C

XID negotiation in wrong state (SNA)

5D

ELLC timeout condition (SNA)

5E

Q-bit discrepancy (SNA)

60

Not assigned

61

DNIC not available

62

Incorrect transit DNIC

64

Facility used incorrectly

67

Incorrect M-bit

70

International Problem / PAD error (SNA)

71

Remote network problem / PAD access facility failure (SNA)

72

International protocol problem / SDLC FCS error (SNA)

73

International link out of order / SDLC timeout (SNA)

74

International link busy / SDLC frame invalid (SNA)

75

Transit network facility problem / I-field too long (SNA)

76

Remote network facility problem / SDLC sequence error (SNA)

77

International routing problem / SDLC frame aborted (SNA)

78

Temporary routing problem / SDLC FRMR received (SNA)

79

Unknown called DNIC / SDLC responce invalid (SNA)

7A

Maintenance action

7B

Invalid paket type

7F

PAD inoperable (SNA)

80

Q-bit error or network not avaible

81

Fast select not substribed / 8100 DPPX-specific (SNA)

82

Cause byte unequal to zero / INN QLLC-specific (SNA)

83

Incompatible paket length

84

Missing M-bit

85

NUI not allowed

86

PVC configuration error

87

CLEAR / RESET by network

88

DNIC not obtainable

89

Reverse changing not subscribed

8A

Not subscribed

8B

Calling address missing

8C

Invalid calling address

8D

Temporary network link problem

8E

Network link out of order

8F

Timer expired in state p1 / INN QLLC-specific (SNA)

90

Invalid cause code

91

Invalid direct call / DDX-P RNR paket received (SNA)

92

Byte not aligned

93

Unexpected facility (X75)

94

Facility not allowed (X75)

95

Invalid address in call accept paket (X75)

96

Interrupt paket not allowed in subnetwork

97

Unexpected reset confirmation

98

Fast select type 2 not allowed

99

Incompatible PVC

9A

Invalid window size negotiated

9B

Incomplete call paket

9C

Invalid address length

9D

Invalid length of facility

9E

Incomplete field

9F

Invalid throughput class

A0

Hunt group out of order

A1

Hunt group not obtainable / Invalid M-bit paket sequence (SNA)

A2

Hunt group temporary out of order / Invalid paket type received (SNA)

A3

Missing address / Invalid paket on PVC (SNA)

A4

Missing subaddress / Unassigned logical channel number (SNA)

A5

Invalid facility format / Diagnostic paket received (SNA)

A6

Facility length unequal to zero / Paket too short (SNA)

A7

Missing user-data / Paket too long (SNA)

A8

Missing national facility / Invalid GFI (SNA)

A9

Access barred / Not identifiable (SNA)

AA

Number temporarily not obtainable / Not supported (SNA)

AB

NUI required in call / Invalid paket send sequence number (SNA)

AC

Fast select not subscribed / Invalid paket receive sequence number (SNA)

AD

Network received download request / Invalid D-bit received (SNA)

AE

Network component failure / Invalid Q-bit received (SNA)

AF

Network internal connection lost

B0

Network internal restart

B1

Invalid adress in call accept / No LU-LU session (SNA)

B2

Unknown facility / Abend 703 in progress (SNA)

B3

Cancel chain command (SNA)

B5

X32 port not available

B6

X32 port not available

B7

-Reserved-

C0

X32 port service data error / X25 dial access invalid service data field

C1

X32/X25 port service data error / Termination pending (SNA)

C2

X32/X25 port user data error / Channel inoperative (SNA)

C3

X32/X25 port procedure error / Unauthorized interrupt confirmation (SNA)

C4

X32/X25 port modem error / Unauthorized interrupt request (SNA)

C5

X32/X25 port modem error / PU resource not available (SNA)

C6

Inactivity time-out (SNA)

C7

Incompatible line configuration (SNA)

C8

X32/X25 port connected / Reset indication to PAD (SNA)

C9

X32/X25 port dialing / DTE not operational (SNA)

D0

Resources - general (SNA)

D1

Buffer depleted (SNA)

D2

PIU too long (SNA)

E0

Local procedure error - general (SNA)

E1

Paket received with LC not equal to zero (SNA)

E2

Restart/Diagnostic paket on LC not equal zero (SNA)

E3

Incoming call received on wrong LC (SNA)

E4

Facility not subscribed (SNA)

E5

Invalid paket for LC equal zero (SNA)

E6

Facility parameters not supported (SNA)

E7

Facility not supported (SNA)

E8

Unexpected calling DTE (SNA)

E9

Invalid D-bit received (SNA)

EA

Reset indication on virtual Call (SNA)

EB

Invalid protocol identifier (SNA)

EC

Connection identifier mismatch (SNA)

ED

Missing cause/diagnostic code (SNA)

F0

Remote procedure error - general (SNA)

FA

Link reset (SNA)

FF

Systemerror


Other Diagnostic-Codes often are used for own mistake codes by communication-device manufacturers.